Crude Oil Lines (Buried) of a leading international oil producer in Indonesia

 

 

Project: Crude Oil Lines (Buried)

Location: Indonesia

Applicator: CV Dian Indah Lestari

Date of Application: September 1999

 

 

The Challenge:


The delivery lines measuring 4” in dia connecting their oil well in the Minas Field had to be frequently replaced within a period of 12 – 18 months regularly because of leaks due to corrosion of the externals   primarily due to their exposure to the existing volcanic soil / moisture. Current protection exercises by applying a coat of bituminous epoxies have failed to solve the corrosion problems.

 

 

The Recommendation:


Corro-Dur 258 was used for this project mainly for the following reasons:

 

1) Environment & user friendly

2) Long term protection

3) Ease of application

4) Resistant to the fluctuating humid environment 

 

 

System Specification:


1)      Grind /Wire brush to remove mill scale from New Pipes.

2)      Carry out a stripe coat of Corro-Dur 258 on all edges/corners by brush

3)      Apply Corro-Dur 258 in two passes to achieve a minimum of 350- 400 microns dft.

4)      Allow to dry for 2 hrs & install

 

 

Conclusion:


Coating was carried out as per above specification & installed within 8 working hours thus reducing down time drastically & also to ensure that the buried pipeline is protected adequately