CAUTION: Protect
eyes and hands.
Do not touch arrow end of glass titrator tube with fingers
|
| 1.
Remove cap from CHLOR-EXTRACT™ solution bottle and pour entire
contents into CHLOR&SLEEVE™. |
|
| 2.
Peal off pressure sensitive blue backing from test sleeve;
then remove t6he air from the test sleeve by squeezing between
fingers and thumb.When extracting air, do not spill CHLOR&EXTRACT
from sleeve. |
|
| 3.
Firmly apply test sleeve to test surface. Lift and hold the
free end of the test sleeve upright to allow extract solution
to come into contact with test surface. Use other hand to
massage the solution through the test sleeve against the surface
for 2 minutes. |
|
| When
massage is complete, remove the test sleeve. For vertical
or overhead surfaces, extract solution will return to lowered
area in test sleeve. For Horizontal surfaces - press and slide
finger across sleeve to move solution to closed end of sleeve
prior to removal. |
|
|
4. Punch out perforated hole in box lid and insert
sleeve with extract solution into the hole in the box
lid.
|
|
5.
Using caution not to touch the ends of the titration tube,
snap off both ends with the metal snapper provided. Then
insert titrator tube into the test sleeve with smaller
numbers and arrow at bottom.
Wait approximately 1 1/2 minutes or until solution is
wicked-up to the top of the titrator tube. Cotton at top
of titrator tube will change color to amber when fully
saturated.
|
 |
6. Immediately
remove and read the number on the titrator tube at the
interface of the color change.Pink is normal,white is
the chloride level.This number is micrograms per centimeter
square (µg/cm2) and parts per million (ppm); the ratio
is 1 to 1 for this test.
When chloride
levels exceed specification requirements, use Corroseal-Chlor*Rid®
liquid soluble salt remover for decontamination.
|
 |
|